STIGUI
V-204655CAT II — Medium severitySV-204655r960927_rule

AAA Services must be configured to use internal system clocks to generate time stamps for audit records.

Rule version SRG-APP-000116-AAA-000320 · STIG v2 · 2026-09-01

Discussion

Without an internal clock used as the reference for the time stored on each event to provide a trusted common reference for the time, forensic analysis would be impeded. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events.

If the internal clock is not used, the system may not be able to provide time stamps for log messages. Additionally, externally generated time stamps may not be accurate. Applications can use the capability of an operating system or purpose-built module for this purpose. Synchronizing the internal clock using NTP provides uniformity for all system clocks over a network. NTP provides an efficient and scalable method for network devices to synchronize to an accurate time source.

Check

Verify AAA Services are configured to use internal system clocks to generate time stamps for audit records.

If AAA Services are not configured to use internal system clocks to generate time stamps for audit records, this is a finding.

Fix

Configure AAA Services to use internal system clocks to generate time stamps for audit records.

Identifiers

Group ID
V-204655
Group title
SRG-APP-000116
Rule ID
SV-204655r960927_rule
Check ID
C-4778r389246_chk
Fix ID
F-4778r389247_fix