STIGUI
V-204695CAT III — Low severitySV-204695r981588_rule

AAA Services must be configured to use at least two NTP servers to synchronize time.

Rule version SRG-APP-000516-AAA-000350 · STIG v2 · 2026-09-01

Discussion

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside of the configured acceptable allowance (drift) may be inaccurate. Additionally, unnecessary synchronization may have an adverse impact on system performance and may indicate malicious activity.

If the internal clock is not used, the system may not be able to provide time stamps for log messages. Additionally, externally generated time stamps may not be accurate. Applications can use the capability of an operating system or purpose-built module for this purpose. Synchronizing the internal clock using NTP provides uniformity for all system clocks over a network. NTP provides an efficient and scalable method for network devices to synchronize to an accurate time source.

Check

Verify AAA Services are configured to use at least two NTP servers to synchronize time. Both a primary and backup NTP server must be identified in the configuration. AAA Services may leverage the capability of an operating system.

If AAA Services are not configured to use at least two separate NTP servers, this is a finding.

Fix

Configure AAA Services to use two separate NTP servers. Both a primary and backup NTP server must be identified in the configuration.

Identifiers

Group ID
V-204695
Group title
SRG-APP-000516
Rule ID
SV-204695r981588_rule
Check ID
C-4818r389366_chk
Fix ID
F-4818r389367_fix