STIGUI
V-276016CAT II — Medium severitySV-276016r1123260_rule

Ax-OS must compare the internal system clocks on an organization-defined frequency with an organization-defined authoritative time source.

Rule version AXOS-00-000080 · STIG v1 · 2025-11-25

Discussion

Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.

Satisfies: SRG-APP-000925, SRG-APP-000371, SRG-APP-000372, SRG-APP-000374, SRG-APP-000920

Check

From the Axonius Toolbox (accessed via Secure Shell [SSH]) Main Actions Menu, select the following options:

System Actions >> Advanced System Actions >> NTP Sources

If any NTP sources listed are not an authoritative time source approved by the authorizing official (AO), this is a finding.

Fix

From the Axonius Toolbox (accessed via SSH) Main Actions Menu, select the following options:

System Actions >> Advanced System Actions >> Configure NTP

Enter the hostname/IP of an AO-approved authoritative time source.

Identifiers

Group ID
V-276016
Group title
SRG-APP-000925
Rule ID
SV-276016r1123260_rule
Check ID
C-80154r1123240_chk
Fix ID
F-80059r1123241_fix