WTM must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for 15 minutes.

Rule version AWTM-NM-000043 · STIG v1 · 2026-09-14

Discussion

By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.

Check

1. Log in to the WTM Web UI. 2. Navigate to Admin >> User Management >> Login Control. 3. Verify "Max Login Attempts" is set to "3". 4. Verify the "CLI Lockout Period (seconds)" is set to "900". 5. Verify the "GUI Lockout Period (seconds)" is set to "900".

If the device is not configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for 15 minutes, this is a finding.

Fix

1. Log in to the WTM Web UI. 2. Navigate to Admin >> User Management >> Login Control. 3. Click "Enable". 4. Set the "Max Login Attempts" to "3". 5. Set the "CLI Lockout Period (seconds)" to "900". 6. Set the "GUI Lockout Period (seconds)" to "900". 7. Click "Commit".

Identifiers

Group ID
V-286495
Group title
SRG-APP-000065-NDM-000214
Rule ID
SV-286495r1273766_rule
Check ID
C-91177r1273764_chk
Fix ID
F-91082r1273765_fix