STIGUI
V-251647CAT II — Medium severitySV-251647r961638_rule

The storage used for data collection by CA IDMS web services must be protected.

Rule version IDMS-DB-000830 · STIG v2 · 2026-06-03

Discussion

Information can be either unintentionally or maliciously disclosed or modified during preparation for transmission, including, for example, during aggregation, at protocol transformation points, and during packing/unpacking. These unauthorized disclosures or modifications compromise the confidentiality or integrity of the information.

Use of this requirement will be limited to situations where the data owner has a strict requirement for ensuring data integrity and confidentiality is maintained at every step of the data transfer and handling process.

When transmitting data, the DBMS, associated applications, and infrastructure must leverage transmission protection mechanisms.

Satisfies: SRG-APP-000441-DB-000378, SRG-APP-000442-DB-000379

Check

Log on to IDMS DC system and issue "DCPROFIL". If SYSTEM STORAGE PROTECTED: display is "NO", this is a finding.

Issue DCMT D PROGRAM RHDCWSSP. If Storage Prot is "NO", this is a finding.

Fix

Use the following system generation parameters to enable the use of standard storage protection:

Set STORAGE KEY parameter of the SYSTEM statement to a value that is not "9". (The value other than 9 is dependent on how the z/OS parm AllowUserKeyCSA is set).

Set PROTECT/NOPROTECT parameter of the SYSTEM statement to "PROTECT".

Set PROTECT/NOPROTECT parameter of the PROGRAM statement to "PROTECT" for RHDCWSSP.

Generate and restart the system.

Identifiers

Group ID
V-251647
Group title
SRG-APP-000441-DB-000378
Rule ID
SV-251647r961638_rule
Check ID
C-55082r807806_chk
Fix ID
F-55036r807807_fix