STIGUI
V-206504CAT III — Low severitySV-206504r961443_rule

Upon receipt of the log record from hosts and devices, the Central Log Server must be configured to record time stamps of the time of receipt that can be mapped to Coordinated Universal Time (UTC).

Rule version SRG-APP-000374-AU-000290 · STIG v3 · 2026-09-01

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.

Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Check

Examine the log records stored on the events server.

Verify the Central Log Server records time stamps of the time the record was received from the host or device.

Verify the time stamp is mapped to UTC.

If the Central Log Server is not configured to record time stamps of the time the record was received or the time stamp is not mapped to UTC, this is a finding.

Fix

Configure the Central Log Server to record time stamps of the time the record was received from the host or device.

Verify the time stamp is mapped to UTC.

Identifiers

Group ID
V-206504
Group title
SRG-APP-000374
Rule ID
SV-206504r961443_rule
Check ID
C-6764r285753_chk
Fix ID
F-6764r285754_fix