STIGUI
V-284910CAT II — Medium severitySV-284910r1212103_rule

The Cisco SNA appliance must be configured to generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Rule version CSNA-ND-000640 · STIG v1 · 2026-07-08

Discussion

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.

Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).

Satisfies: SRG-APP-000360-NDM-000295, SRG-APP-000795-NDM-000130

Check

Determine if the Cisco SNA appliance is configured to generate an immediate alert of all audit failure events requiring real-time alerts.

Navigate to SNA Dashboard >> Configure >> Central Management >> Actions... >> Edit Appliance Configuration >> General Tab >> SMTP Configuration.

Verify an SMTP server is configured (e.g., port, From Email, User Name, Password and Encryption Type).

Navigate to SNA Dashboard >> Configure >> Central Management >> Actions... >> Edit Appliance Configuration >> General Tab >> DODIN Notifications.

Verify "DODIN Notifications" is "Enabled" and sent to an appropriate email address.

If an immediate alert of all audit failure events requiring real-time alerts is not generated, this is a finding.

Fix

Configure the Cisco SNA appliance to generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Navigate to SNA Dashboard >> Configure >> Central Management >> Actions... >> Edit Appliance Configuration >> General Tab >> SMTP Configuration.

Input the SMTP server settings (e.g., SMTP Server, Port, From Email, User Name, Password and Encryption Type).

Select "Apply Settings".

Note: The encryption type must be SMTPS or STARTTLS.

Navigate to SNA Dashboard >> Configure >> Central Management >> Actions... >> Edit Appliance Configuration >> General Tab >> DODIN Notifications.

Click "Enable DODIN Notifications" and set the appropriate email address.

Select "Apply Settings".

Identifiers

Group ID
V-284910
Group title
SRG-APP-000360-NDM-000295
Rule ID
SV-284910r1212103_rule
Check ID
C-89480r1212101_chk
Fix ID
F-89385r1212102_fix