STIGUI
V-269533CAT II — Medium severitySV-269533r1050416_rule

The chronyd service must be enabled.

Rule version ALMA-09-055130 · STIG v1 · 2026-08-25

Discussion

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.

Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network.

Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).

Satisfies: SRG-OS-000355-GPOS-00143, SRG-OS-000359-GPOS-00146

Check

Verify the chronyd service is active with the following command:

$ systemctl is-active chronyd

active

If the chronyd service is not active, this is a finding.

Fix

To enable the chronyd service run the following command:

$ systemctl enable --now chronyd

Identifiers

Group ID
V-269533
Group title
SRG-OS-000355-GPOS-00143
Rule ID
SV-269533r1050416_rule
Check ID
C-73564r1048975_chk
Fix ID
F-73465r1048976_fix