STIGUI
V-233182CAT II — Medium severitySV-233182r961446_rule

The container platform must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.

Rule version SRG-APP-000375-CTR-000870 · STIG v2 · 2026-09-01

Discussion

To properly investigate an event, it is important to have enough granularity within the time stamps to determine the chronological order of the audited events. Without this granularity, events may be interpreted out of proper sequence, thus hobbling the investigation or causing the investigation to come to inaccurate conclusions.

Time stamps generated by the container platform include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.

Check

Review the container platform documentation and configuration files to determine if time stamps for log records meet a granularity of one second.

If the time stamp cannot generate to a one-second granularity, this is a finding.

Fix

Configure the container platform to use time stamps for log records that can meet a granularity of one second.

Identifiers

Group ID
V-233182
Group title
SRG-APP-000375
Rule ID
SV-233182r961446_rule
Check ID
C-36118r601033_chk
Fix ID
F-36086r601034_fix