Rule version SRG-APP-000925-DB-000330 · STIG v4 · 2026-08-31
Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.
Verify the DBMS is configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.
If the DBMS is not configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source, this is a finding.
Configure the DBMS to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.