STIGUI
V-234181CAT II — Medium severitySV-234181r961860_rule

The FortiGate device must off-load audit records on to a different system or media than the system being audited.

Rule version FGFW-ND-000110 · STIG v1 · 2026-08-24

Discussion

Information stored in one location is vulnerable to accidental or incidental deletion or alteration.

Offloading is a common process in information systems with limited audit storage capacity.

Check

Verify remote logging is configured.

Via the GUI:

Login via the FortiGate GUI with super-admin privileges.

- Navigate to Log and Report. - Navigate to Log Settings. - Verify the Remote and Archiving settings.

or

Via the CLI:

Open a CLI console via SSH or from the "CLI Console" button in the GUI.

Run the following commands to verify which logging settings are enabled:

# show full-configuration log fortianalyzer setting | grep -i 'status\|server' # show full-configuration log fortianalyzer2 setting | grep -i 'status\|server' # show full-configuration log fortianalyzer3 setting | grep -i 'status\|server' # show full-configuration log syslogd setting | grep -i 'status\|server' # show full-configuration log syslogd2 setting | grep -i 'status\|server' # show full-configuration log syslogd3 setting | grep -i 'status\|server' # show full-configuration log syslogd4 setting | grep -i 'status\|server' - The output should indicate enabled and an IP address.

If the FortiGate is not logging to a fortianalyzer or syslog server, this is a finding.

Fix

Login via the GUI with super-admin privileges.

1. Click Log and Report. 2. Click Log Settings.

To add a FortiAnalyzer: - In the Remote Logging and Archiving, enable logging to FortiAnalyzer and provide the IP address.

To add a Syslog server: - In the Remote Logging and Archiving, enable Send logs to Syslog and provide the IP address.

3. Apply changes.

or

1. Open a CLI console via SSH or from the "CLI Console" button in the GUI.

2. Configure a fortianalyzer or syslog server with the following commands:

FortiAnalyzer: # config log fortianalyzer setting # set status enable # set server {IP Address} # set upload-option realtime # end

Syslog: # config log syslogd setting # set status enable # set server {IP Address} # set mode reliable # end

Identifiers

Group ID
V-234181
Group title
SRG-APP-000515-NDM-000325
Rule ID
SV-234181r961860_rule
Check ID
C-37366r863252_chk
Fix ID
F-37331r863253_fix