STIGUI
V-233324CAT II — Medium severitySV-233324r1270651_rule

Forescout must off-load log records onto a different system. This is required for compliance with C2C Step 1.

Rule version FORE-NC-000160 · STIG v2 · 2026-09-01

Discussion

Having a separate, secure location for log records is essential to the preservation of logs as required by policy.

Satisfies: SRG-NET-000492-NAC-002110, SRG-NET-000334-NAC-001350

Check

If DoW is not at C2C Step 1 or higher, this is not a finding.

1. Go to Tools >> Options >> Syslog. 2. Verify a syslog server's IP address is configured.

Or

1. Go to Tools >> Options. 2. Navigate to the extended module (e.g., Splunk) that offloads log records to a separate device. 3. Verify the connection is successful.

If each Forescout device does not offload log records to a separate device, this is a finding.

Fix

Configure Syslog server with TCP, as well as configure Syslog to alert if the communication between the Syslog server and the Forescout appliance loses connectivity.

1. Go to Tools >> Options >> Syslog. 2. Click "Add/Edit". 3. Configure the Syslog: - Navigate to Syslog Server IP address >> Server Port >> Server Protocol set to TCP. - Check the Use TLS setting. - Configure the Identity, Facility, and Severity. 4. Click "Ok". 5. Click "Apply".

Or

Configure external module (e.g., Splunk) per instructions to send appliance logs from each Forescout appliance to the separate destination.

Identifiers

Group ID
V-233324
Group title
SRG-NET-000334-NAC-001350
Rule ID
SV-233324r1270651_rule
Check ID
C-36519r1270650_chk
Fix ID
F-36484r1113795_fix