STIGUI
V-230941CAT III — Low severitySV-230941r961830_rule

Forescout must generate log records showing starting and ending time for administrator access to the system.

Rule version FORE-NM-000130 · STIG v2 · 2026-09-01

Discussion

Without generating log records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one.

Log records can be generated from various components within the network device (e.g., module or policy filter).

Check

Verify the syslog trigger is configured.

1. Log on to Forescout Administrator UI with admin or operator credentials. 2. From the menu, select Tools >> Options >> Modules >> Syslog >> Syslog Triggers. 3. Under User Operations, verify "Include user operations" is checked.

If Forescout does not generate log records showing starting and ending time for administrator access to the system, this is a finding.

Fix

Configure the syslog trigger.

1. Log on to Forescout Administrator UI with admin or operator credentials. 2. From the menu, select Tools >> Options >> Modules >> Syslog >> Syslog Triggers. 3. Under User Operations, check "Include user operations".

Identifiers

Group ID
V-230941
Group title
SRG-APP-000505-NDM-000322
Rule ID
SV-230941r961830_rule
Check ID
C-33871r603662_chk
Fix ID
F-33844r603663_fix