STIGUI
V-255283CAT II — Medium severitySV-255283r958788_rule

The HPE 3PAR OS must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Rule version HP3P-33-001701 · STIG v2 · 2024-08-27

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.

Time stamps generated by the operating system include date and time. Time is commonly expressed in UTC, a modern continuation of GMT, or local time with an offset from UTC.

Check

To verify the time zone is configured, enter:

cli% showdate

If the time zone field is not configured, this is a finding.

Fix

Configure the time zone by first identifying the time zone indicator:

cli% setdate -tzlist

Then configure the timezone with:

cli% setdate -tz <timezone identifier from above>

If UTC is to be used, complete the operation with:

cli% setdate -tz Etc/UTC

Verify the timezone is set with: cli% showdate

Identifiers

Group ID
V-255283
Group title
SRG-OS-000359-GPOS-00146
Rule ID
SV-255283r958788_rule
Check ID
C-58956r870166_chk
Fix ID
F-58900r870167_fix