STIGUI
V-214639CAT II — Medium severitySV-214639r382903_rule

The HP FlexFabric Switch must be configured to disable non-essential capabilities.

Rule version HFFS-L2-000001 · STIG v1 · 2026-09-10

Discussion

A compromised switch introduces risk to the entire network infrastructure as well as data resources that are accessible via the network. The perimeter defense has no oversight or control of attacks by malicious users within the network. Preventing network breaches from within is dependent on implementing a comprehensive defense-in-depth strategy, including securing each device connected to the network. This is accomplished by following and implementing all security guidance applicable for each node type. A fundamental step in securing each switch is to enable only the capabilities required for operation.

Check

Review the HP FlexFabric Switch configuration to determine if services or functions not required for operation, or not related to switch functionality, are enabled.

If unnecessary services and functions are enabled on the HP FlexFabric Switch, this is a finding.

[HP] display ftp-server FTP is not configured.

[HP] display current-configuration | include telnet

Note: When Telnet server is enabled, the output for this command is telnet server enable.

Fix

Remove unneeded services and functions from the HP FlexFabric Switch. Removal is recommended since the service or function may be inadvertently enabled otherwise. However, if removal is not possible, disable the service or function.

Disable unsecure protocols and services on the HP FlexFabric Switch:

[HP] undo ftp server enable [HP] undo telnet server enable

Note: By default, both FTP and Telnet services are disabled.

Identifiers

Group ID
V-214639
Group title
SRG-NET-000131-L2S-000014
Rule ID
SV-214639r382903_rule
Check ID
C-15842r368670_chk
Fix ID
F-15840r368671_fix