The HP FlexFabric Switch must initiate session auditing upon startup.
Severity | Group ID | Group Title | Version | Rule ID | Date | STIG Version |
|---|---|---|---|---|---|---|
| low | V-217439 | SRG-APP-000092-NDM-000224 | HFFS-ND-000025 | SV-217439r960888_rule | 2025-06-12 | 1 |
| Description |
|---|
| If auditing is enabled late in the startup process, the actions of some start-up processes may not be audited. Some audit systems also maintain state information only available if auditing is enabled before a given process is created. |
| ℹ️ Check |
|---|
| Determine if the info-center feature is enabled on the HP FlexFabric Switch: [HP] display info-center Information Center: Enabled If logging is not enabled, this is a finding. |
| ✔️ Fix |
|---|
| Enable info-center feature on the HP FlexFabric Switch: [HP] info-center enable Note: By default, the information center is enabled. |