The HP FlexFabric Switch must initiate session auditing upon startup.
Severity | Group ID | Group Title | Version | Rule ID | Date | STIG Version |
|---|---|---|---|---|---|---|
| low | V-217439 | SRG-APP-000092-NDM-000224 | HFFS-ND-000025 | SV-217439r960888_rule | 2025-06-12 | 1 |
Description
If auditing is enabled late in the startup process, the actions of some start-up processes may not be audited. Some audit systems also maintain state information only available if auditing is enabled before a given process is created.
ℹ️ Check
Determine if the info-center feature is enabled on the HP FlexFabric Switch:
[HP] display info-center
Information Center: Enabled
If logging is not enabled, this is a finding.
✔️ Fix
Enable info-center feature on the HP FlexFabric Switch:
[HP] info-center enable
Note: By default, the information center is enabled.