Discussion

If auditing is enabled late in the startup process, the actions of some start-up processes may not be audited. Some audit systems also maintain state information only available if auditing is enabled before a given process is created.

Check

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Fix

Enable info-center feature on the HP FlexFabric Switch:

[HP] info-center enable

Note: By default, the information center is enabled.

Identifiers

Group ID
V-217439
Group title
SRG-APP-000092-NDM-000224
Rule ID
SV-217439r960888_rule
Check ID
C-18663r292992_chk
Fix ID
F-18661r292993_fix