STIGUI
V-217464CAT II — Medium severitySV-217464r961401_rule

The HP FlexFabric Switch must generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Rule version HFFS-ND-000097 · STIG v1 · 2026-09-02

Discussion

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.

Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).

Check

Determine if the HP FlexFabric Switch provides the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time.

[HP] display info-center

Information Center: Enabled Console: Enabled Monitor: Enabled Log host: Enabled 192.100.50.27, port number: 514, host facility: local7 Log buffer: Enabled Max buffer size 1024, current buffer size 512 Current messages 66, dropped messages 0, overwritten messages 0 Log file: Enabled Security log file: Enabled Information timestamp format: Log host: Date Other output destination: Date

If the HP FlexFabric Switch does not provide the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time, this is a finding.

Fix

Configure the HP FlexFabric Switch to generate an immediate real-time alert of all audit failure events requiring real-time alerts.

[HP] info-center enable

Identifiers

Group ID
V-217464
Group title
SRG-APP-000360-NDM-000295
Rule ID
SV-217464r961401_rule
Check ID
C-18688r293067_chk
Fix ID
F-18686r293068_fix