STIGUI
V-217472CAT II — Medium severitySV-217472r961800_rule

The HP FlexFabric Switch must generate audit records when successful/unsuccessful attempts to modify administrator privileges occur.

Rule version HFFS-ND-000120 · STIG v1 · 2026-09-02

Discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one.

Audit records can be generated from various components within the HP FlexFabric Switch (e.g., module or policy filter).

Check

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Fix

Enable info-center feature on the HP FlexFabric Switch:

[HP] info-center enable

Note: By default, the information center is enabled.

Identifiers

Group ID
V-217472
Group title
SRG-APP-000495-NDM-000318
Rule ID
SV-217472r961800_rule
Check ID
C-18696r293091_chk
Fix ID
F-18694r293092_fix