The HP FlexFabric Switch must generate audit records showing starting and ending time for administrator access to the system.

Rule version HFFS-ND-000124 · STIG v1 · 2026-09-02

Discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one.

Audit records can be generated from various components within the HP FlexFabric Switch (e.g., module or policy filter).

Check

Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.

Fix

Enable info-center feature on the HP FlexFabric Switch:

[HP] info-center enable

Note: By default, the information center is enabled.