STIGUI
V-65241CAT II — Medium severitySV-79731r1_rule

The DataPower Gateway must have ICMP responses disabled on all interfaces facing untrusted networks.

Rule version WSDP-AG-000061 · STIG v1 · 2016-01-21

Discussion

Providing too much information in error messages risks compromising the data and security of the application and system. Organizations carefully consider the structure/content of error messages. The required information within error messages will vary based on the protocol and error condition. Information that could be exploited by adversaries includes, for example, ICMP messages that reveal the use of firewalls or access-control lists.

The DataPower appliance, by default, will respond to ICMP pings, Info requests, and Address Mask queries. This must be disabled on any interface facing an untrusted network or network with a lower security posture.

Check

View each interface that is connected to a network that is less trusted or untrusted. In the DataPower web interface, navigate to Ethernet interface >> Network settings >> Internet Control Message Protocol (ICMP) Disable.

If the Administrative State is not "Disable", this is a finding.

Fix

In the DataPower web interface, navigate to Ethernet interface >> Network settings >> Internet Control Message Protocol (ICMP) Disable. Set the Administrative State to "Disable".

Identifiers

Group ID
V-65241
Group title
SRG-NET-000273-ALG-000129
Rule ID
SV-79731r1_rule
Check ID
C-65869r1_chk
Fix ID
F-71181r1_fix