STIGUI
V-65317CAT II — Medium severitySV-79807r1_rule

The DataPower Gateway must not use 0.0.0.0 as a listening IP address for any service.

Rule version WSDP-AG-000151 · STIG v1 · 2016-01-21

Discussion

Using 0.0.0.0 as a listening address allows all interfaces to receive traffic for the service. This creates an unnecessary exposure when services are configured to listen on this address.

Check

Go to Default domain.

Click Status >> Main >> Active Services >> Click Show All Domains.

Review IP addresses assigned to active services. If any list 0.0.0.0, this is a finding.

Fix

Log on to each active domain.

Click Objects >> Protocol Handlers >> HTTP Front Side Handlers.

Click on the name of any Handler listed that uses the IP Address of 0.0.0.0.

Change the IP Address >> Click Apply.

Click Objects >> Protocol Handlers >> HTTPS Front Side Handlers.

Click on the name of any Handler listed that uses the IP Address of 0.0.0.0.

Change the IP Address >> Click Apply >> Click Save Configuration.

Identifiers

Group ID
V-65317
Group title
SRG-NET-000364-ALG-000122
Rule ID
SV-79807r1_rule
Check ID
C-65945r1_chk
Fix ID
F-71257r1_fix