STIGUI
V-65105CAT II — Medium severitySV-79595r1_rule

The DataPower Gateway must use mechanisms meeting the requirements of applicable federal laws, Executive Orders, directives, policies, regulations, standards, and guidance for authentication to a cryptographic module.

Rule version WSDP-NM-000067 · STIG v1 · 2017-10-05

Discussion

Unapproved mechanisms that are used for authentication to the cryptographic module are not verified and therefore cannot be relied upon to provide confidentiality or integrity, and DoD data may be compromised.

Network devices utilizing encryption are required to use FIPS-compliant mechanisms for authenticating to cryptographic modules.

FIPS 140-2 is the current standard for validating that mechanisms used to access cryptographic modules utilize authentication that meets DoD requirements.

Check

Default domain >> Status >> Cryptographic Mode Status: If Target=Permissive AND Current=Permissive AND Pending Target=Permissive, this is a finding.

Fix

Administration >> Access >> RBM Settings >> Password Policy. Change Password hash algorithm to sha256crypt.

Administration >> Miscellaneous >> Crypto Tools. Set Cryptographic Mode to FIPS 140-2 Level 1 and click Set Cryptographic Mode button.

Control Panel >> System Control >> Shutdown. Set Mode to Reload Firmware >> Click "Shutdown" button.

Identifiers

Group ID
V-65105
Group title
SRG-APP-000179-NDM-000265
Rule ID
SV-79595r1_rule
Check ID
C-65733r1_chk
Fix ID
F-71045r1_fix