The DataPower Gateway must use automated mechanisms to alert security personnel to threats identified by authoritative sources (e.g., CTOs) and in accordance with CJCSM 6510.01B.
Severity | Group ID | Group Title | Version | Rule ID | Date | STIG Version |
|---|---|---|---|---|---|---|
| medium | V-65173 | SRG-APP-000516-NDM-000333 | WSDP-NM-000131 | SV-79663r1_rule | 2017-10-05 | 1 |
| Description |
|---|
| By immediately displaying an alarm message, potential security violations can be identified more quickly even when administrators are not logged into the network device. An example of a mechanism to facilitate this would be through the utilization of SNMP traps. |
| ℹ️ Check |
|---|
| Go to Administration >> Access >> SNMP Settings. Verify the IP address, port, and security settings. Go to the Trap and Notification Targets tab. Verify the remote server/receiver information. If these values have not been set, this is a finding. |
| ✔️ Fix |
|---|
| Go to Administration >> Access >> SNMP Settings. Configure the IP address, port, and security settings. Go to the Trap and Notification Targets tab. Enter the remote server/receiver information. |