STIGUI
V-223553CAT II — Medium severitySV-223553r1226013_rule

IBM z/OS PARMLIB CLOCKxx must have the Accuracy PARM coded properly.

Rule version ACF2-OS-000170 · STIG v9 · 2026-09-01

Discussion

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time, a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.

Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network.

Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).

Check

Refer to the CLOCKxx member of PARMLIB.

If the ACCURACY parm is not coded, this is a finding.

If the ACCURACY parm is coded to "1000", this is not a finding.

Fix

Define the CLOCKxx statement to include the ACCURACY parm set to "1000".

Identifiers

Group ID
V-223553
Group title
SRG-OS-000356-GPOS-00144
Rule ID
SV-223553r1226013_rule
Check ID
C-25226r500794_chk
Fix ID
F-25214r500795_fix