STIGUI
V-223205CAT II — Medium severitySV-223205r1015751_rule

The Juniper SRX Services Gateway must be configured to synchronize internal information system clocks with the primary and secondary NTP servers for the network.

Rule version JUSX-DM-000094 · STIG v3 · 2024-12-20

Discussion

The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on log events and other functions.

Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources.

Check

Verify the Juniper SRX is configured to synchronize internal information system clocks with the primary and secondary NTP sources.

[edit] show system ntp

If the Juniper SRX is not configured to synchronize internal information system clocks with an NTP server, this is a finding.

Fix

The following commands allow the device to keep time synchronized with the network. To designate a primary NTP server, add the “prefer” keyword to the server statement.

[edit] set system ntp server <NTP-server1-IP> prefer set system ntp source-address <MGT-IP-Address> set system ntp server <NTP-server2-IP> set system ntp source-address <MGT-IP-Address>

Identifiers

Group ID
V-223205
Group title
SRG-APP-000373-NDM-000298
Rule ID
SV-223205r1015751_rule
Check ID
C-24878r513302_chk
Fix ID
F-24866r513303_fix