STIGUI
V-263667CAT II — Medium severitySV-263667r1137762_rule

The layer 2 switch must implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions.

Rule version SRG-NET-000715-L2S-000120 · STIG v3 · 2026-02-12

Discussion

Separating critical system components and functions from other noncritical system components and functions through separate subnetworks may be necessary to reduce susceptibility to a catastrophic or debilitating breach or compromise that results in system failure. For example, physically separating the command and control function from the in-flight entertainment function through separate subnetworks in a commercial aircraft provides an increased level of assurance in the trustworthiness of critical system functions.

This requirement also applies to Zero Trust initiatives.

Check

Verify the layer 2 switch is configured to implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions.

If the layer 2 switch is not configured to implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions, this is a finding.

Fix

Configure the layer 2 switch to implement physically or logically separate subnetworks to isolate organization-defined critical system components and functions.

Identifiers

Group ID
V-263667
Group title
SRG-NET-000715
Rule ID
SV-263667r1137762_rule
Check ID
C-67580r982572_chk
Fix ID
F-67488r982275_fix