STIGUI
V-220821CAT II — Medium severitySV-220821r1051027_rule

Users must be prompted for a password on resume from sleep (on battery).

Rule version WN10-CC-000145 · STIG v3 · 2025-09-24

Discussion

Authentication must always be required when accessing a system. This setting ensures the user is prompted for a password on resume from sleep (on battery).

Check

If the following registry value does not exist or is not configured as specified, this is a finding:

Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \SOFTWARE\Policies\Microsoft\Power\PowerSettings\0e796bdb-100d-47d6-a2d5-f7d2daa51f51\

Value Name: DCSettingIndex

Value Type: REG_DWORD Value: 1

Fix

Configure the policy value for Computer Configuration >> Administrative Templates >> System >> Power Management >> Sleep Settings >> "Require a password when a computer wakes (on battery)" to "Enabled".

Identifiers

Group ID
V-220821
Group title
SRG-OS-000373-GPOS-00156
Rule ID
SV-220821r1051027_rule
Check ID
C-22536r554948_chk
Fix ID
F-22525r554949_fix