STIGUI
V-238162CAT II — Medium severitySV-238162r879573_rule

Enabling IE Bind to Object functionality must be present.

Rule version DTOO111 · STIG v2 · 2024-02-21

Discussion

Internet Explorer performs a number of safety checks before initializing an ActiveX control. It will not initialize a control if the kill bit for the control is set in the registry, or if the security settings for the zone in which the control is located do not allow it to be initialized. This functionality can be controlled separately for instances of Internet Explorer spawned by Office applications (for example, if a user clicks a link in an Office document or selects a menu option that loads a web page). A security risk could occur if potentially dangerous controls are allowed to load.

Check

Verify the policy value for Computer Configuration -> Administrative Templates -> Microsoft Office 2016 (Machine) -> Security Settings -> IE Security "Bind to Object" is set to "Enabled" and 'excel.exe' is checked.

Procedure: Use the Windows Registry Editor to navigate to the following key:

HKLM\Software\Microsoft\Internet Explorer\Main\FeatureControl\FEATURE_SAFE_BINDTOOBJECT

Criteria: If the value excel.exe is REG_DWORD = 1, this is not a finding.

Fix

Set the policy value for Computer Configuration -> Administrative Templates -> Microsoft Office 2016 (Machine) -> Security Settings -> IE Security "Bind to Object" to "Enabled" and place a check in the 'excel.exe' check box.

Identifiers

Group ID
V-238162
Group title
SRG-APP-000112
Rule ID
SV-238162r879573_rule
Check ID
C-41372r652417_chk
Fix ID
F-41331r652418_fix