STIGUI
V-70727CAT II — Medium severitySV-85351r1_rule

Untrusted intranet zone access to Project servers must not be allowed.

Rule version DTOO346 · STIG v1 · 2016-11-02

Discussion

Allows users to access Project Server Web sites and Workspaces that have not been added to their trusted internet zones. If you enable this setting, users can access Project Server and Microsoft SharePoint Foundation sites that are not in their trusted internet zones. If this setting is disabled or not configured, users are required to add the Project Server and Microsoft SharePoint Foundation sites to their trusted internet site zones.

Check

Verify the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" is set to "Disabled".

Procedure: Use the Windows Registry Editor to navigate to the following key:

HKCU\Software\Policies\Microsoft\Office\16.0\ms project\security

Criteria: If the value TrustWSS is REG_DWORD = 0, this is not a finding.

Fix

Set the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" to "Disabled".

Identifiers

Group ID
V-70727
Group title
SRG-APP-000210
Rule ID
SV-85351r1_rule
Check ID
C-71211r3_chk
Fix ID
F-77053r1_fix