STIGUI
V-202125CAT II — Medium severitySV-202125r961830_rule

The network device must generate audit records showing starting and ending time for administrator access to the system.

Rule version SRG-APP-000505-NDM-000322 · STIG v5 · 2026-05-23

Discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one.

Audit records can be generated from various components within the network device (e.g., module or policy filter).

Check

Determine if the network device generates audit records showing starting and ending time for administrator access to the system.

If the network device does not generate audit records showing starting and ending time for administrator access to the system, this is a finding.

Fix

Configure the network device to generate audit records showing starting and ending time for administrator access to the system.

Identifiers

Group ID
V-202125
Group title
SRG-APP-000505
Rule ID
SV-202125r961830_rule
Check ID
C-2251r382055_chk
Fix ID
F-2252r382056_fix