STIGUI
V-219988CAT II — Medium severitySV-219988r958768_rule

The audit system must support an audit reduction capability.

Rule version SOL-11.1-010060 · STIG v3 · 2026-08-19

Discussion

Using the audit system will utilize the audit reduction capability. Without an audit reduction capability, users find it difficult to identify specific patterns of attack.

Check

The Audit Configuration profile is required.

This check applies to the global zone only. Determine the zone that you are currently securing.

# zonename

If the command output is "global", this check applies.

Check the status of the audit system. It must be auditing.

# pfexec auditconfig -getcond

If this command does not report:

audit condition = auditing

this is a finding.

Fix

The Audit Control profile is required.

This action applies to the global zone only. Determine the zone that you are currently securing.

# zonename

If the command output is "global", this action applies.

If auditing has been disabled, it must be enabled with the following command:

# pfexec audit -s

Identifiers

Group ID
V-219988
Group title
SRG-OS-000349
Rule ID
SV-219988r958768_rule
Check ID
C-21698r372418_chk
Fix ID
F-21697r372419_fix