The Edge SWG must fail securely in the event of an operational failure.

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-279222SRG-NET-000365-ALG-000123SYME-00-010200SV-279222r1170676_rule2025-12-161
Description
If a boundary protection device fails in an unsecure manner (open), information external to the boundary protection device may enter, or the device may permit unauthorized information release. Secure failure ensures when a boundary control device fails, all traffic will be subsequently denied. Fail secure is a condition achieved by employing information system mechanisms to ensure, in the event of operational failures of boundary protection devices at managed interfaces (e.g., routers, firewalls, guards, and application gateways residing on protected subnetworks commonly referred to as demilitarized zones), information systems do not enter into unsecure states where intended security properties no longer hold.
ℹ️ Check
1. Log in to the Integrated Secure Gateway (ISG) SSH CLI. 2. Enter "enable" and "configure terminal". 3. Enter "bridge view". If the mode for the bridge in use does not state "fail-closed", this is a finding.
✔️ Fix
1. Log in to the Integrated Secure Gateway (ISG) SSH CLI. 2. Enter "enable" and "configure terminal". 3. Enter "bridge view". 4. Find the bridge in use for the Edge SWG, e.g., "passthru-2:0". 5. Enter "bridge edit passthru-2:0 mode fail-closed".