STIGUI
V-94671CAT II — Medium severitySV-104501r1_rule

Symantec ProxySG must compare internal information system clocks at least every 24 hours with an authoritative time server.

Rule version SYMP-NM-000100 · STIG v1 · 2019-12-20

Discussion

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside of the configured acceptable allowance (drift) may be inaccurate. Additionally, unnecessary synchronization may have an adverse impact on system performance and may indicate malicious activity. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network.

Check

Verify the Symantec ProxySG is configured to use authoritative NTP servers (the NTP protocol itself enforces periodic checks at least every 24 hours).

1. Log on to the Web Management Console. 2. Click Configuration >> General >> Clock. 3. Confirm that the value of the "Query interval (minutes)" field is at least 1440 (24 hours in minutes). 4. Click "NTP", and confirm that the desired authoritative time servers are present.

If Symantec ProxySG does not compare internal information system clocks at least every 24 hours with an authoritative time server, this is a finding.

Fix

Configure the Symantec ProxySG to use authoritative NTP servers (the NTP protocol itself enforces periodic checks at least every 24 hours).

1. Log on to the Web Management Console. 2. Select "Configuration", then "General", then "Clock". 3. Enter the desired time sync period into the "Query interval (minutes) field and click Apply. 4. Click "NTP", then "New", then "Add" and enter each desired authoritative time server. 5. Click "Apply".

Identifiers

Group ID
V-94671
Group title
SRG-APP-000371-NDM-000296
Rule ID
SV-104501r1_rule
Check ID
C-93861r1_chk
Fix ID
F-100789r1_fix