STIGUI
V-253073CAT II — Medium severitySV-253073r1262387_rule

TOSS must disable network management of the chrony daemon.

Rule version TOSS-04-040180 · STIG v2 · 2026-08-20

Discussion

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time when a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.

Not exposing the management interface of the chrony daemon on the network diminishes the attack space.

TOSS utilizes the "timedatectl" command to view the status of the "systemd-timesyncd.service." The "timedatectl" status will display the local time, UTC, and the offset from UTC.

Note that USNO offers authenticated NTP service to DoW and U.S. Government agencies operating on the NIPR and SIPR networks. Visit https://www.usno.navy.mil/USNO/time/ntp/DoW-customers for more information.

Check

Verify TOSS disables network management of the chrony daemon with the following command:

$ sudo grep -w 'cmdport' /etc/chrony.conf

cmdport 0

If the "cmdport" option is not set to "0", is commented out or missing, this is a finding.

Fix

Configure the operating system disable network management of the chrony daemon by adding/modifying the following line in the /etc/chrony.conf file.

cmdport 0

Identifiers

Group ID
V-253073
Group title
SRG-OS-000095-GPOS-00049
Rule ID
SV-253073r1262387_rule
Check ID
C-56526r824889_chk
Fix ID
F-56476r824890_fix