STIGUI
V-282570CAT II — Medium severitySV-282570r1200690_rule

TOSS 5 must notify the system administrator (SA) and information system security officer (ISSO) (at a minimum) when allocated audit record storage volume 75 percent utilization.

Rule version TOSS-05-000392 · STIG v1 · 2026-08-20

Discussion

If security personnel are not notified immediately when storage volume reaches 75 percent utilization, they are unable to plan for audit record storage capacity expansion.

Check

Verify TOSS 5 notifies the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75 percent of the repository maximum audit record storage capacity using the following command:

$ sudo grep -w space_left_action /etc/audit/auditd.conf

space_left_action = email

If the value of the "space_left_action" is not set to "email", or if the line is commented out, ask the SA to indicate how the system is providing real-time alerts to the SA and ISSO.

If there is no evidence that real-time alerts are configured on the system, this is a finding.

Fix

Configure TOSS 5 to initiate an action to notify the SA and ISSO (at a minimum) when allocated audit record storage volume reaches 75 percent of the repository maximum audit record storage capacity by adding/modifying the following line in the /etc/audit/auditd.conf file.

space_left_action = email

Identifiers

Group ID
V-282570
Group title
SRG-OS-000343-GPOS-00134
Rule ID
SV-282570r1200690_rule
Check ID
C-87131r1200688_chk
Fix ID
F-87036r1200689_fix