TOSS 5 must have the chrony package installed.

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-282574SRG-OS-000355-GPOS-00143TOSS-05-000200SV-282574r1200702_rule2026-04-011

Description

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.

ℹ️ Check

Verify TOSS 5 has the "chrony" package installed using the following command: $ sudo dnf list --installed chrony Example output: chrony.x86_64 4.1-3.el9 If the "chrony" package is not installed, this is a finding.

✔️ Fix

The "chrony" package can be installed using the following command: $ sudo dnf install chrony