The UEM server must enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period.

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-234310SRG-APP-000065SRG-APP-000065-UEM-000036SV-234310r960840_rule2025-09-102

Description

By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute forcing, is reduced. Limits are imposed by locking the account. Satisfies:FMT_SMF.1(2)b. Reference:PP-MDM-431028

ℹ️ Check

Requirement is Not Applicable when the UEM server is configured to use DoD Central Directory Service for administrator account authentication. Verify the UEM server enforces the limit of three consecutive invalid logon attempts by a user during a 15-minute time period. If the UEM server does not enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period, this is a finding.

✔️ Fix

Configure the UEM server to enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period.