STIGUI
V-206357CAT II — Medium severitySV-206357r960888_rule

The web server must initiate session logging upon start up.

Rule version SRG-APP-000092-WSR-000055 · STIG v4 · 2026-05-23

Discussion

An attacker can compromise a web server during the startup process. If logging is not initiated until all the web server processes are started, key information may be missed and not available during a forensic investigation. To assure all logable events are captured, the web server must begin logging once the first web server process is initiated.

Check

Review the web server documentation and deployed configuration to determine if the web server captures log data as soon as the web server is started.

If the web server does not capture logable events upon startup, this is a finding.

Fix

Configure the web server to capture logable events upon startup.

Identifiers

Group ID
V-206357
Group title
SRG-APP-000092
Rule ID
SV-206357r960888_rule
Check ID
C-6618r377663_chk
Fix ID
F-6618r377664_fix