STIGUI
V-224590CAT II — Medium severitySV-224590r1145947_rule

BMC CONTROL-O configuration/parameter values are not specified properly.

Rule version ZCTO0041 · STIG v7 · 2025-09-28

Discussion

BMC CONTROL-O configuration/parameters control the security and operational characteristics of products. If these parameter values are improperly specified, security and operational controls may be weakened. This exposure may threaten the availability of the product applications, and compromise the confidentiality of customer data.

Check

Refer to the following applicable report produced by the z/OS Data Collection:

- IOA.RPT(CTOPARM).

Automated Analysis Refer to the following report produced by the z/OS Data Collection:

- PDI(ZCTO0041).

If the following keywords specify the values in the BMC CONTROL-O security parameter member, this is not a finding.

Keyword Value RUNTDFT OWNER RUNTCACH 100 AUTOMLOG V

Fix

The BMC CONTROL-O Systems programmer will verify that any configuration/parameters that are required to control the security of the product are properly configured and syntactically correct. Set the standard values for the BMC CONTROL-O security parameters for the specific Access Control Program (ACP) environment along with additional IOA security parameters with standard values as documented below.

Keyword Value RUNTDFT OWNER RUNTCACH 100 AUTOMLOG V

Identifiers

Group ID
V-224590
Group title
SRG-OS-000080
Rule ID
SV-224590r1145947_rule
Check ID
C-26273r1145945_chk
Fix ID
F-26261r1145946_fix