STIGUI
V-224421CAT II — Medium severitySV-224421r1144870_rule

BMC IOA Started task(s) must be properly defined to the STARTED resource class for RACF.

Rule version ZIOAR032 · STIG v7 · 2025-09-27

Discussion

Access to product resources must be restricted to only individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could compromise the operating system, ACP, and customer data.

Check

Refer to the following report produced by the RACF Data Collection:

- DSMON.RPT(RACSPT).

Automated Analysis Refer to the following report produced by the RACF Data Collection:

- PDI(ZIOA0032).

Verify that the BMC IOA started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry, this is a finding.

Fix

The BMC IOA system programmer and the ISSO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.

A unique userid must be assigned for the BMC IOA started task(s) thru a corresponding STARTED class entry.

The following sample set of commands is shown here as a guideline:

rdef started IOAGATE.** uacc(none) owner(admin) audit(all(read)) stdata(user(IOAGATE) group(stc))

setr racl(started) ref

Identifiers

Group ID
V-224421
Group title
SRG-OS-000104
Rule ID
SV-224421r1144870_rule
Check ID
C-26098r1144868_chk
Fix ID
F-26086r1144869_fix