BMC Mainview for z/OS Started task(s) must be properly defined to the Started Task Table ACID for Top Secret.

Rule version ZMVZT032 · STIG v7 · 2025-09-28

Discussion

Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.

Check

Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(#STC).

Automated Analysis Refer to the following report produced by the TSS Data Collection:

- PDI(ZMVZ0032).

If the BMC Mainview for z/OS started task(s) is (are) defined in the TSS STC record, this is not a finding.

Fix

The BMC Mainview for z/OS systems programmer and the ISSO will ensure that a product's started task(s) is (are) properly identified and/or defined to the system ACP.

A unique ACID must be assigned for the BMC Mainview for z/OS started task(s) through a corresponding STC table entry.

The following sample set of commands is shown here as a guideline:

TSS ADD(STC) PROCNAME(MV$CAS) ACID(MV$CAS) TSS ADD(STC) PROCNAME(MV$MVS) ACID(MV$MVS)