STIGUI
V-224613CAT II — Medium severitySV-224613r1146087_rule

BMC Mainview for z/OS Resource Class must be defined or active in the ACP.

Rule version ZMVZT038 · STIG v7 · 2025-09-28

Discussion

Failure to use a robust ACP to control a product could potentially compromise the integrity and availability of the MVS operating system and user data.

Check

Refer to the following report produced by the ACP Data Collection:

- TSSCMDS.RPT(#RDT).

If the BMC Mainview for z/OS Resource Class(es) is (are) defined in the Resource Definition Table (RDT) as follows, this is not a finding.

RESOURCE CLASS = class RESOURCE CODE = X'hex code' ATTRIBUTE = MASK|NOMASK,MAXOWN(08),MAXPERMIT(044),ACCESS,DEFPROT ACCESS = NONE(0000),CONTROL(0400),UPDATE(6000),READ(4000) ACCESS = WRITE(2000),ALL(FFFF) DEFACC = READ

Fix

The ISSO will ensure the BMC Mainview for z/OS resource class(es) is (are) defined in the TSS RDT.

(Note: The RESCLASS and/or RESCODE identified below are examples of a possible installation. The actual RESCLASS and/or RESCODE values are determined when the product is actually installed on a system through the product's installation guide and can be site specific.)

Use the following commands as an example:

TSS ADDTO(RDT) RESCLASS(BMCVIEW) - RESCODE(3B) DEFACC(READ) - ATTR(MASK|NOMASK,DEFPROT,LONG,GENERIC) - ACLST(NONE,READ,UPDATE,ALL)

Identifiers

Group ID
V-224613
Group title
SRG-OS-000309
Rule ID
SV-224613r1146087_rule
Check ID
C-26296r1146086_chk
Fix ID
F-26284r868740_fix