STIGUI
V-224294CAT II — Medium severitySV-224294r1144191_rule

Compuware Abend-AID Started Task name will be properly identified and/or defined to the system ACP.

Rule version ZAIDA030 · STIG v7 · 2025-09-27

Discussion

Compuware Abend-AID requires a started task that will be restricted to certain resources, datasets, and other system functions. Defining the started task as a userid to the system ACP allows the ACP to control the access and authorized users that require these capabilities. Failure to properly control these capabilities could compromise the operating system environment, ACP, and customer data.

Check

Refer to the following report produced by the ACF2 Data Collection:

- ACF2CMDS.RPT(ATTSTC).

Verify that the logonid(s) for the Compuware Abend-AID started task(s) is (are) properly defined. If the following attributes are defined, this is not a finding.

STC

Fix

The ISSO working with the systems programmer will ensure the Compuware Abend-AID Started Task(s) is properly identified and/or defined to the System ACP.

If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes.

Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.

The following commands are provided as a sample for defining Started Task(s):

SET LID insert AAVIEWER stc name('STC, Compuware Abend-AID Viewer') insert BDCAS stc name('STC, Compuware Abend-AID') insert TDCAS stc name('STC, Compuware Abend-AID for CICS')

Identifiers

Group ID
V-224294
Group title
SRG-OS-000104
Rule ID
SV-224294r1144191_rule
Check ID
C-25967r1141339_chk
Fix ID
F-25955r1141340_fix