V-224665CAT II — Medium severitySV-224665r1145799_rule

Compuware Abend-AID Started task will be properly defined to the Started Task Table for Top Secret.

Rule version ZAIDT032 · STIG v7 · 2025-09-28

Discussion

Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.

Check

Refer to the following report produced by the TSS Data Collection:

- TSSCMDS.RPT(#STC).

Automated Analysis Refer to the following report produced by the TSS Data Collection:

- PDI(ZAID0032).

If the Compuware Abend-AID started task(s) is (are) defined in the TSS STC record, this is not a finding.

Fix

The ISSO working with the systems programmer will ensure the Compuware Abend-AID Started Task(s) is properly identified and/or defined to the system ACP.

A unique ACID must be assigned for the Compuware Abend-AID started task(s) through a corresponding STC table entry.

The following commands are provided as a sample for defining Started Task(s):

TSS ADD(STC) PROCNAME(AAVIEWER) ACID(AAVIEWER) TSS ADD(STC) PROCNAME(BDCAS) ACID(BDCAS) TSS ADD(STC) PROCNAME(TDCAS) ACID(TDCAS)

Identifiers

Group ID
V-224665
Group title
SRG-OS-000104
Rule ID
SV-224665r1145799_rule
Check ID
C-26348r1145797_chk
Fix ID
F-26336r1145798_fix