STIGUI
V-224540CAT II — Medium severitySV-224540r1144997_rule

IBM Tivoli Asset Discovery for zOS (TADz) Started task(s) must be properly defined to the STARTED resource class for RACF.

Rule version ZTADR032 · STIG v7 · 2025-09-27

Discussion

Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.

Check

Refer to the following report produced by the RACF Data Collection:

- DSMON.RPT(RACSPT).

Automated Analysis Refer to the following report produced by the RACF Data Collection:

- PDI(ZTAD0032).

Verify that the IBM Tivoli Asset Discovery for zOS (TADz) started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry, this is not a finding.

Fix

The IBM Tivoli Asset Discovery for zOS (TADz) system programmer and the ISSO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.

A unique userid must be assigned for the IBM Tivoli Asset Discovery for zOS (TADz) started task(s) thru a corresponding STARTED class entry.

The following sample set of commands is shown here as a guideline:

rdef started TADZMON.** uacc(none) owner(admin) audit(all(read)) stdata(user(TADZMON) group(stc))

setr racl(started) ref

Identifiers

Group ID
V-224540
Group title
SRG-OS-000104
Rule ID
SV-224540r1144997_rule
Check ID
C-26223r1144995_chk
Fix ID
F-26211r1144996_fix