CylanceON-PREM must be configured to send alerts via Simple Mail Transfer Protocol (SMTP).
Severity | Group ID | Group Title | Version | Rule ID | Date | STIG Version |
|---|---|---|---|---|---|---|
| medium | V-272634 | SRG-APP-000275 | CYLN-OP-000560 | SV-272634r1113494_rule | 2025-06-11 | 1 |
Description
Failure to notify personnel of failed tests introduces a risk to the system. Corrective action and the unsecure condition(s) will remain.
Satisfies: SRG-APP-000275, SRG-APP-000279, SRG-APP-000940
ℹ️ Check
Verify SMTP Settings. Administrator privileges are required.
1. Log in to the admin console.
2. Navigate to CONFIGURATION >> Settings.
3. Find SMTP.
If SMTP is not enabled, this is a finding.
If SMTP settings are not populated and event type notifications not enabled, this is a finding.
✔️ Fix
Configure SMTP Settings. Administrator privileges are required.
1. Log in to the admin console.
2. Navigate to CONFIGURATION >> Settings.
3. Find SMTP and click on the edit button.
4. Slide the button to enable.
5. Populate the Syslog/SIEM configuration.
6. Click the green check to save.