STIGUI
V-279450CAT II — Medium severitySV-279450r1265228_rule

Nutanix AOS must configure Network Time Protocol (NTP).

Rule version NXAC-AS-000051 · STIG v1 · 2026-08-27

Discussion

Time synchronization of system clocks is essential for the correct execution of many system services, including identification and authentication processes that involve certificates and time-of-day restrictions as part of access control. Denial of service or failure to deny expired credentials may result without properly synchronized clocks within and between systems and system components. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. The granularity of time measurements refers to the degree of synchronization between system clocks and reference clocks, such as clocks synchronizing within hundreds of milliseconds or tens of milliseconds. Organizations may define different time granularities for system components. Time service can be critical to other security capabilities such as access control and identification and authentication, depending on the nature of the mechanisms used to support the capabilities.

Satisfies: SRG-APP-000920-AS-000320, SRG-APP-000371-AS-000077

Check

Confirm the Prism Element is configured to use an authoritative NTP source.

1. Log in to Prism Element. 2. Click the gear icon in the upper-right corner. 3. Navigate to "NTP Servers". 4. Verify external NTP servers have been configured.

If external NTP sources are not configured, this is a finding.

Fix

Configure the Prism Element to use an authoritative NTP time source.

1. Log in to Prism Element. 2. Click the gear icon in the upper-right corner. 3. Navigate to "NTP Servers". 4. Configure an authoritative NTP server.

Identifiers

Group ID
V-279450
Group title
SRG-APP-000920-AS-000320
Rule ID
SV-279450r1265228_rule
Check ID
C-84003r1192365_chk
Fix ID
F-83908r1191135_fix