STIGUI
V-284306CAT II — Medium severitySV-284306r1224049_rule

The Omnissa WS1 UEM server must be configured to record time stamps for audit records in Coordinated Universal Time (UTC).

Rule version OMW1-00-006600 · STIG v1 · 2026-08-31

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.

Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of GMT, or local time with an offset from UTC.

Satisfies: FAU_GEN.1.2(1) Satisfies: SRG-APP-000374-UEM-000244, SRG-APP-000375-UEM-000245

Check

Authenticate to the Workspace ONE UEM console as an administrator.

Navigate to Groups & Settings >> All Settings >> System >> Enterprise Integration >> Syslog.

If "Syslog Format" is not set to "RFC-5424 Format", this is a finding.

Fix

Authenticate to the Workspace ONE UEM console as an administrator.

Navigate to Groups & Settings >> All Settings >> System >> Enterprise Integration >> Syslog.

Next to "Syslog Format" select "RFC-5424 Format" from the drop-down menu. Click "Save".

Identifiers

Group ID
V-284306
Group title
SRG-APP-000374-UEM-000244
Rule ID
SV-284306r1224049_rule
Check ID
C-88870r1211908_chk
Fix ID
F-88775r1211961_fix