STIGUI
V-256086CAT II — Medium severitySV-256086r961443_rule

The Riverbed NetProfiler must be configured to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC).

Rule version RINP-DM-000048 · STIG v2 · 2024-08-27

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.

Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Check

Go to Administration >> General Settings.

Under "Time Configuration", verify the Time Zone is set to "UTC".

If the Time Zone is not "UTC", this is a finding.

Fix

Go to Administration >> General Settings.

Under "Time Configuration", configure the Time Zone to "UTC".

Identifiers

Group ID
V-256086
Group title
SRG-APP-000374-NDM-000299
Rule ID
SV-256086r961443_rule
Check ID
C-59760r882764_chk
Fix ID
F-59703r882765_fix