V-256087CAT II — Medium severitySV-256087r997789_rule

The Riverbed NetProfiler must be configured to record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.

Rule version RINP-DM-000049 · STIG v2 · 2024-08-27

Discussion

Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.

Check

Go to Administration >> General Settings.

Under "Time Configuration", verify that redundant NTP servers have been configured.

If NTP is not configured, this is a finding.

Fix

Go to Administration >> General Settings.

Under "Time Configuration", enable and configure redundant NTP servers.

This requirement is part of using the NTP protocol.

Identifiers

Group ID
V-256087
Group title
SRG-APP-000375-NDM-000300
Rule ID
SV-256087r997789_rule
Check ID
C-59761r882767_chk
Fix ID
F-59704r882768_fix